SSG UPS Industrial Wide Temperature

The Falcon SSG industrial UPS system delivers reliable protection in harsh environments with a wide temperature UPS -20°C to +55°C operating range and full UL 1778, cUL, CE, and UL 508 certifications. The wide temperature UPS offers 1.5 to 6kVA in rackmount UPS & tower UPS formats. Designed as a true on-line industrial UPS system with long-life batteries rated up to 12 years, it reduces maintenance costs while ensuring dependable performance. Expandable battery UPS banks and options such as NEMA 3R industrial UPS enclosures, remote management, and environmental monitoring provide flexibility for critical applications. Backed by Falcon’s reputation for quality and reliability, the SSG wide temperature UPS is built for long-term industrial UPS power supply use.

Products

Key Features

Compare a Standard UPS to a Falcon UPS products

Feature
Standard UPS
SSG (Wide temperature UPS)
SSGRP-H (Extreme-Temp)
SSG-RP (Ultra-wide Temp)
Operating Temperature Range
Typically 0°C to +40°C, (designed to operate in controlled environments)
-20°C to +55°C
-40°C to +70°C
-30°C to +65°C
UPS Design
Standby or line interactive topologies provide minimal level of protection against power problems. Not designed for critical applications.
True on-line (double-conversion) industrial
True on-line (double-conversion) industrial
True on-line (double-conversion) industrial
Battery Life
Generic use VRLA battery ~3 - 5 years at 25°C; sensitive to temperature changes affecting overall battery service life.
12-year at 25°C (≈4-year at 50°C)
10-year at 25°C
10-year at 25°C
Battery Runtime
Limited expansion for UPS autonomy. The generic runtime only provides a few minutes to power down connected equipment.
1.5 kVA: 6 / 18 min; up to 106 / 240 min with four ext. banks
1.5 kVA: 12.5 / 29 min (full/half); up to 98 / 200 min with four ext. banks
1.5 kVA: 12.5 / 28 min; up to 98 / 200 min with four ext. banks
Options & Communications
Generic UPS monitoring via USB or RS232. Office-grade design for controlled environments.
USB, RS-232, remote emergency power off (REPO), available remote management card (SNMP/HTTP), dry-contact relay card, extended battery banks, maintenance bypass switch (MBS), environmental protection (conformal coating and powder coating), isolation transformers, NEMA 3R enclosures for outdoor applications
Operating Temperature Range
Standard UPS:
Typically 0°C to +40°C, (designed to operate in controlled environments).
SSG (Wide-temp):
-20°C to +55°C
SSGRP-H (Extreme-Temp):
-40°C to +70°C
SSG-RP (Ultra-wide Temp):
-30°C to +65°C
UPS Design
Standard UPS:
Standby or line interactive topologies provide minimal level of protection against power problems. Not designed for critical applications.
SSG (Wide-temp):
True on-line (double-conversion) industrial
SSGRP-H (Extreme-Temp):
True on-line (double-conversion) industrial
SSG-RP (Ultra-wide Temp):
True on-line (double-conversion) industrial
Battery Life
Standard UPS:
Generic use VRLA battery ~3 - 5 years at 25°C; sensitive to temperature changes affecting overall battery service life.
SSG (Wide-temp):
12-year at 25°C (≈4-year at 50°C)
SSGRP-H (Extreme-Temp):
10-year at 25°C
SSG-RP (Ultra-wide Temp):
10-year at 25°C
Battery Runtime
Standard UPS:
Limited expansion for UPS autonomy. The generic runtime only provides a few minutes to power down connected equipment.
SSG (Wide-temp):
1.5 kVA: 6 / 18 min; up to 106 / 240 min with four ext. banks.
SSGRP-H (Extreme-Temp):
1.5 kVA: 12.5 / 29 min (full/half); up to 98 / 200 min with four ext. banks
SSG-RP (Ultra-wide Temp):
1.5 kVA: 12.5 / 28 min; up to 98 / 200 min with four ext. banks.
Options & Communications
Standard UPS:
Generic UPS monitoring via USB or RS232. Office-grade design for controlled environments.
SSG (Wide-temp):
USB, RS-232, remote emergency power off (REPO), available remote management card (SNMP/HTTP), dry-contact relay card, extended battery banks, maintenance bypass switch (MBS), environmental protection (conformal coating and powder coating), isolation transformers, NEMA 3R enclosures for outdoor applications.
SSGRP-H (Extreme-Temp):
USB, RS-232, remote emergency power off (REPO), available remote management card (SNMP/HTTP), dry-contact relay card, extended battery banks, maintenance bypass switch (MBS), environmental protection (conformal coating and powder coating), isolation transformers, NEMA 3R enclosures for outdoor applications.
SSG-RP (Ultra-wide Temp):
USB, RS-232, remote emergency power off (REPO), available remote management card (SNMP/HTTP), dry-contact relay card, extended battery banks, maintenance bypass switch (MBS), environmental protection (conformal coating and powder coating), isolation transformers, NEMA 3R enclosures for outdoor applications.

Upgrade and SAVE

Get 30% off an upgraded SSG Rackmount and Tower models from now until December 31, 2025.

*Promotion valid for existing Falcon Electric customers who purchased SSG Rackmount and Tower models from 2017 – 2024.

Battery Options & Chargers

Accessories & peripherals

Maintenance Bypass Switch (MBS)

For All SSG Rackmount Model MBS

MB1K-1
MB1K-2
MB2K-1
MB2K-2
MB3K-1
MB3K-2

Maintenance Bypass Switch (MBS)

Communications

For All SSG Rackmount Models

Dry Contact Relay Card
Compatible with SSG and SSG-RP UPS Models

Wide Temperature UPS Remote Management Card
Compatible with SSG and SSG-RP UPS Models

Communications

Environmental Protection

All SSG-RP Rackmount Models
  • Conformal-S
  • Conformal-SC
Environmental Protection

Industries

Falcon’s wide temperature UPS can be found in various industries including but not limited to these markets

Applications

  • Automotive Assembly Plant
  • Battery Energy Storage
  • Cameras
  • Cell sites
  • Central offices & core data centers
  • Central Operations & Control
  • Communication Systems
  • Edge/MEC nodes & micro data centers
  • Electronics & Semiconductor Facility
  • Field/Remote & Security Infrastructure
  • Food & Beverage Processing Center
  • Geothermal
  • Hydroelectric
  • Microgrids
  • Offshore Platform
  • Oil Rigs
  • Outside Remote Plants
  • Payment Processing
  • Pharmaceutical & Biotech Manufacturing
  • Refineries and Processing Plants
  • Remote Sites / Pipelines
  • Solar
  • Tolling Infrastructures
  • Traffic Management Signals
  • Treatment Process Areas
  • Water Distribution & Storage System
  • Wind

Need a custom solution?

Tell us about your project and we can design a wide temperature UPS that fits your needs?

Talk to Us
worker

Case Studies

Related News